Radiology physics and radiation protection

This page is for the attention of healthcare professionals only.

The Radiology Physics section within MIMP covers medical physics, safety and technical support to a range of patient services. Our radiation and imaging domains are broadly divided into ionising and non-ionising radiations, with specialist knowledge, advice, quality assurance testing and compliance support for each area.

Non-ionising radiations

  • Laser physics 
  • UV light physics
  • MR physics
  • Ultrasound physics

Ionising radiations

  • Diagnostic radiology physics
  • Radioactive substances
  • Radiation safety
  • Radiation protection

 

 For information or to book Quality Assurance, email: sth.QABookings@nhs.net

For diagnostic radiology physics queries, contact: sth.DRphysics@nhs.net

For staff dose or environmental monitoring queries, email: sth.DRphysics@nhs.net

To request a dose estimate for a radiation incident, foetal exposure, or high skin dose, contact: sth.doseincidents@nhs.net

For MRI physics email: sth.mrsafety@nhs.net

For non-ionising radiations email: sth.nirQA@nhs.net

Postal address:

Radiology Physics, I floor

Royal Hallamshire Hospital

Glossop Road

Sheffield

S10 2JF

Further information

The team at DR Physics carry out the acceptance, commissioning, routine QA and troubleshooting for radiographic equipment. X-ray, fluoro, angio, CT, mammography, dental x-ray and bone densitometry are the main areas that use ionising radiation for imaging – and require our regular QA visits for compliance with IR(ME)R regulations.

Radiation incidents, high skin dose procedures and foetal dose requests are notified to us for dose calculations and advice via sth.doseincidents@nhs.net. The forms necessary for these scenarios and more are available via the Radiation Safety and Governance SharePoint page

Looking at setting DRLs? Or maybe evaluating new radiographic equipment? Perhaps you are looking to improve patient doses or image quality. Talk to our Medical Physics Experts for support with these processes.

Our radiation protection services support compliance with IRR regulations – from shielding calculations for x-ray rooms to staff radiation dosimetry, we offer our clients RPA expert advice.

IRR

  • Staff safety
  • Public safety
  • RPS, RPA
  • Controlled and supervised areas
  • Local rules
  • Risk assessment
  • Contingency plans
  • Dose limitation
  • Staff radiation incidents
  • Inspected by HSE

IR(ME)R

  • Patient safety
  • Carers and comforters
  • MPE, CRE
  • Employer’s procedures
  • Justification
  • Referrer, Practitioner, Operator
  • Optimisation of exposures
  • Patient radiation incidents
  • Programmes of biomedical research involving ionising radiation
  • Inspected by CQC

Contact our team: 

For information or to book Quality Assurance, email: sth.QABookings@nhs.net
For diagnostic radiology physics queries, contact: sth.DRphysics@nhs.net
For staff dose or environmental monitoring queries, email: sth.DRphysics@nhs.net
To request a dose estimate for a radiation incident, foetal exposure, or high skin dose, contact: sth.doseincidents@nhs.net

The MR Physics team provides expert advice and technical support to ensure safe, effective and efficient delivery of MRI services across STH and the wider region. We lead a comprehensive quality assurance programme and support installation of new scanners from procurement and site design through to commissioning.

The team delivers safety education and training to a range of staff groups, and both develops and maintains robust safety policies. Working closely with radiographers and radiologists, we drive service improvements through optimisation of imaging protocols and delivery of clinically focussed research and development.

Contact our team on sth.mrsafety@nhs.net

The non-ionising radiation team provides the Trust with scientific support in the areas of ultrasound and optical radiation.  The team is comprised of clinical scientists and clinical technologists.

We provide procurement advice & safety advice, commission equipment and perform routine quality assurance of image quality or treatment dosimetry.  For clinical lasers we provide a Laser Protection Advisory service.  We collaborate with clinical and scientific colleagues in service development and research.  We work with national organisations and contribute to national guidance in these areas.

If you have a query on the imaging performance of your ultrasound system, need advice on optical radiation safety & dosimetry or would like to collaborate on a service development please reach out to us at sth.nirqa@nhs.net or Prashant.verma@nhs.net

 

Our experienced team provides Radiation Protection Adviser (RPA), Radioactive Waste Adviser (RWA), scientific and technology services for the safe use of sealed and unsealed radioactive sources in nuclear medicine and laboratories. We also provide RPA and RWA services to radiotherapy departments – including external beam, brachytherapy and gamma knife modalities.  

We provide services to assist clients to achieve compliance with the Ionising Radiations Regulations 2017 (IRR2017) and Environmental Permitting Regulation 2016. We also give advice concerning the transport of radioactive substances and emergency preparedness.  

 

Our key advisory services include:

  • IRR2017 HSE consenting of nuclear medicine and radiotherapy practices
  • The drafting  and review of radiation safety policies and procedures.
  • Risk assessments and dose assessments
  • The designation of Radiation Controlled and Radiation Supervised Areas (IRR2017, Regulation 17) and suitable monitoring regimes
  • Radiation safety aspects of the design, construction and modification of premises
  • The monitoring of personal whole body and extremity doses in accordance with IRR2017, Including advice on classifying staff and arrangements for outside workers
  • Assistance with incident and high dose investigations.
  • Advice on all aspects of compliance with environmental permits for radioactive substances including security of radioactive substances and the disposal of radioactive waste;
  • Liaison with Environment Agency, HSE, Counter Terrorism Security Advisers (CTSAs), Dangerous Goods Safety Advisers (DGSAs) as appropriate and accompanying Inspectors during visits
  • Training requirements of staff for compliance with regulations;          
  • Radon

Our practical technical and scientific services cover:

  • The testing and examination of radiation protection instruments (IRR2017, regulation 20)
  • Leak testing of sealed sources (IRR2017, regulation 28)
  • The measurement of environmental doses using sensitive TLDs (IRR2017, regulations 12(3) and regulation 20)